Low energy consumption due to multi-layer insulation.
To withstand harsh use in the laboratory, e.g. when heat-treating metals, robust insulation with light refractory bricks is necessary. The chamber furnaces N 7/H – N 87/H are a perfect fit to solve this problem. The furnaces can be extended with a variety of accessories, like annealing boxes for operation under protective gas, roller guides, or a cooling station with a quench tank. Even high-performance applications like the annealing of titanium in medical applications can be implemented without the use of expensive and complicated annealing systems.
Standard Equipment
- Tmax 1280 °C
- Deep furnace chamber with three-sides heating: from both side walls and bottom
- Heating elements on support tubes ensure free heat radiation and a long service life
- Bottom heating protected by heat-resistant SiC plate
- Temperature uniformity up to +/− 10 °C according to DIN 17052-1
- Low energy consumption due to multi-layer insulation
- Base frame included in the delivery, N 7/H – N 17/HR designed as table-top model
- Parallel guided downward swinging door (user protected from heat radiation)
- Door movement cushioned with gas dampers/struts
- Controller B500 (5 prgrams with each 4 segments)
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Specification
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions1 in mm | Connected | Electrical | Weight | Heating time | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
in °C | w | d | h | in l | W | D | H | load in kW | connection* | in kg | in min2 | |
N 7/H | 1280 | 250 | 250 | 140 | 9 | 800 | 650 | 600 | 3.0 | 1-phase | 60 | 320 |
N 11/H | 1280 | 250 | 350 | 140 | 11 | 800 | 750 | 600 | 3.5 | 1-phase | 70 | 320 |
N 11/HR | 1280 | 250 | 350 | 140 | 11 | 800 | 750 | 600 | 5.5 | 3-phase3 | 70 | 70 |
N 17/HR | 1280 | 250 | 500 | 140 | 17 | 800 | 900 | 600 | 6.4 | 3-phase3 | 90 | 110 |
N 31/H | 1280 | 350 | 350 | 250 | 31 | 1040 | 1030 | 1340 | 15.0 | 3-phase | 210 | 90 |
N 41/H | 1280 | 350 | 500 | 250 | 41 | 1040 | 1180 | 1340 | 15.0 | 3-phase | 260 | 105 |
N 61/H | 1280 | 350 | 750 | 250 | 61 | 1040 | 1430 | 1340 | 20.0 | 3-phase | 400 | 105 |
N 87/H | 1280 | 350 | 1000 | 250 | 87 | 1040 | 1680 | 1340 | 25.0 | 3-phase | 480 | 105 |
1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.*Please see page 75 for more information about supply voltage 2Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE rsp. 400 V 3/N/PE) 3Heating only between two phases |