<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Muffle Furnaces | Laboratory Supplies Company (Pty) Ltd</title>
	<atom:link href="https://www.labsupply.co.za/product-category/furnaces/muffle-furnaces/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.labsupply.co.za/product-category/furnaces/muffle-furnaces/</link>
	<description></description>
	<lastBuildDate>Thu, 15 Feb 2024 13:11:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.labsupply.co.za/wp-content/uploads/2022/06/lab-supply-logo-100x100.png</url>
	<title>Muffle Furnaces | Laboratory Supplies Company (Pty) Ltd</title>
	<link>https://www.labsupply.co.za/product-category/furnaces/muffle-furnaces/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Chamber Furnaces with Brick Insulation or Fiber Insulation up to 1400 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/chamber-furnaces-with-brick-insulation-or-fiber-insulation-up-to-1400-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 13:11:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19131</guid>

					<description><![CDATA[<p>These big chamber furnaces LH 15/12 - LF 120/14 have been trusted for many years as professional chamber furnaces for the laboratory. These furnaces are available with either a robust insulation of light refractory bricks (LH models) or with a combination insulation of refractory bricks in the corners and low heat storage, quickly cooling fiber material (LF models). With a wide variety of optional equipment, these chamber furnaces can be optimally adapted to your processes.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1200 °C, 1300 °C, or 1400 °C</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>High furnace chamber with five-sided heating for very good temperature uniformity</li>
<li>Heating elements on support tubes ensure free heat radiation and a long service life</li>
<li>Controller mounted on furnace door and removable for comfortable operation</li>
<li>Protection of bottom heating and flat stacking surface provided by embedded SiC plate in the floor</li>
<li>LH models: multi-layered insulation of light refractory bricks and special backup insulation</li>
<li>LF models: high-quality fiber insulation with corner bricks for shorter heating and cooling times</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Door with brick-on-brick seal, hand fitted</li>
<li>Gegenerously dimensioned heating provides for short heating times</li>
<li>Self-supporting arch for high stability and greatest possible protection against dust</li>
<li>Motorized exhaust air flaps</li>
<li>Freely adjustable air inlet integrated in furnace floor</li>
<li>Base included</li>
<li>Controller B500 (5 programs with each 4 segments)</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/chamber-furnaces-with-brick-insulation-or-fiber-insulation-up-to-1400-c/">Chamber Furnaces with Brick Insulation or Fiber Insulation up to 1400 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>LH models: multi-layered insulation of light refractory bricks and special backup insulation.</p>
<p>LF models: high-quality fiber insulation with corner bricks for shorter heating and cooling times.</p>
<p>These big chamber furnaces LH 15/12 &#8211; LF 120/14 have been trusted for many years as professional chamber furnaces for the laboratory. These furnaces are available with either a robust insulation of light refractory bricks (LH models) or with a combination insulation of refractory bricks in the corners and low heat storage, quickly cooling fiber material (LF models). With a wide variety of optional equipment, these chamber furnaces can be optimally adapted to your processes.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1200 °C, 1300 °C, or 1400 °C</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>High furnace chamber with five-sided heating for very good temperature uniformity</li>
<li>Heating elements on support tubes ensure free heat radiation and a long service life</li>
<li>Controller mounted on furnace door and removable for comfortable operation</li>
<li>Protection of bottom heating and flat stacking surface provided by embedded SiC plate in the floor</li>
<li>LH models: multi-layered insulation of light refractory bricks and special backup insulation</li>
<li>LF models: high-quality fiber insulation with corner bricks for shorter heating and cooling times</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Door with brick-on-brick seal, hand fitted</li>
<li>Gegenerously dimensioned heating provides for short heating times</li>
<li>Self-supporting arch for high stability and greatest possible protection against dust</li>
<li>Motorized exhaust air flaps</li>
<li>Freely adjustable air inlet integrated in furnace floor</li>
<li>Base included</li>
<li>Controller B500 (5 programs with each 4 segments)</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Model</th>
<th>Tmax</th>
<th colspan="3">Inner dimensions in mm</th>
<th>Volume</th>
<th colspan="3">Outer dimensions<sup class="hks">1</sup> in mm</th>
<th>Connected</th>
<th>Electrical</th>
<th>Weight</th>
</tr>
<tr>
<th class="model"></th>
<th>in °C</th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in l</th>
<th>W</th>
<th>D</th>
<th>H</th>
<th>load in kW</th>
<th>connection*</th>
<th>in kg</th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">LH 15/12</td>
<td class="prodtd2">1200</td>
<td class="prodtd3">250</td>
<td class="prodtd4">250</td>
<td class="prodtd5">250</td>
<td class="prodtd6">15</td>
<td class="prodtd7">680</td>
<td class="prodtd8">860</td>
<td class="prodtd9">1230</td>
<td class="prodtd10">5.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">170</td>
</tr>
<tr>
<td class="model prodtd1">LH 30/12</td>
<td class="prodtd2">1200</td>
<td class="prodtd3">320</td>
<td class="prodtd4">320</td>
<td class="prodtd5">320</td>
<td class="prodtd6">30</td>
<td class="prodtd7">710</td>
<td class="prodtd8">930</td>
<td class="prodtd9">1290</td>
<td class="prodtd10">7.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">200</td>
</tr>
<tr>
<td class="model prodtd1">LH 60/12</td>
<td class="prodtd2">1200</td>
<td class="prodtd3">400</td>
<td class="prodtd4">400</td>
<td class="prodtd5">400</td>
<td class="prodtd6">60</td>
<td class="prodtd7">790</td>
<td class="prodtd8">1080</td>
<td class="prodtd9">1370</td>
<td class="prodtd10">8.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">300</td>
</tr>
<tr>
<td class="model prodtd1">LH 120/12</td>
<td class="prodtd2">1200</td>
<td class="prodtd3">500</td>
<td class="prodtd4">500</td>
<td class="prodtd5">500</td>
<td class="prodtd6">120</td>
<td class="prodtd7">890</td>
<td class="prodtd8">1180</td>
<td class="prodtd9">1470</td>
<td class="prodtd10">12.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">410</td>
</tr>
<tr>
<td class="model prodtd1">LH 216/12</td>
<td class="prodtd2">1200</td>
<td class="prodtd3">600</td>
<td class="prodtd4">600</td>
<td class="prodtd5">600</td>
<td class="prodtd6">216</td>
<td class="prodtd7">990</td>
<td class="prodtd8">1280</td>
<td class="prodtd9">1590</td>
<td class="prodtd10">20.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">450</td>
</tr>
<tr>
<td class="model prodtd1"></td>
<td class="prodtd2"></td>
<td class="prodtd3"></td>
<td class="prodtd4"></td>
<td class="prodtd5"></td>
<td class="prodtd6"></td>
<td class="prodtd7"></td>
<td class="prodtd8"></td>
<td class="prodtd9"></td>
<td class="prodtd10"></td>
<td class="prodtd11"></td>
<td class="prodtd12"></td>
</tr>
<tr>
<td class="model prodtd1">LH 15/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">250</td>
<td class="prodtd4">250</td>
<td class="prodtd5">250</td>
<td class="prodtd6">15</td>
<td class="prodtd7">680</td>
<td class="prodtd8">860</td>
<td class="prodtd9">1230</td>
<td class="prodtd10">7.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">170</td>
</tr>
<tr>
<td class="model prodtd1">LH 30/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">320</td>
<td class="prodtd4">320</td>
<td class="prodtd5">320</td>
<td class="prodtd6">30</td>
<td class="prodtd7">710</td>
<td class="prodtd8">930</td>
<td class="prodtd9">1290</td>
<td class="prodtd10">8.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">200</td>
</tr>
<tr>
<td class="model prodtd1">LH 60/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">400</td>
<td class="prodtd4">400</td>
<td class="prodtd5">400</td>
<td class="prodtd6">60</td>
<td class="prodtd7">790</td>
<td class="prodtd8">1080</td>
<td class="prodtd9">1370</td>
<td class="prodtd10">11.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">300</td>
</tr>
<tr>
<td class="model prodtd1">LH 120/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">500</td>
<td class="prodtd4">500</td>
<td class="prodtd5">500</td>
<td class="prodtd6">120</td>
<td class="prodtd7">890</td>
<td class="prodtd8">1180</td>
<td class="prodtd9">1470</td>
<td class="prodtd10">15.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">410</td>
</tr>
<tr>
<td class="model prodtd1">LH 216/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">600</td>
<td class="prodtd4">600</td>
<td class="prodtd5">600</td>
<td class="prodtd6">216</td>
<td class="prodtd7">990</td>
<td class="prodtd8">1280</td>
<td class="prodtd9">1590</td>
<td class="prodtd10">22.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">460</td>
</tr>
<tr>
<td class="model prodtd1"></td>
<td class="prodtd2"></td>
<td class="prodtd3"></td>
<td class="prodtd4"></td>
<td class="prodtd5"></td>
<td class="prodtd6"></td>
<td class="prodtd7"></td>
<td class="prodtd8"></td>
<td class="prodtd9"></td>
<td class="prodtd10"></td>
<td class="prodtd11"></td>
<td class="prodtd12"></td>
</tr>
<tr>
<td class="model prodtd1">LH 15/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">250</td>
<td class="prodtd4">250</td>
<td class="prodtd5">250</td>
<td class="prodtd6">15</td>
<td class="prodtd7">680</td>
<td class="prodtd8">860</td>
<td class="prodtd9">1230</td>
<td class="prodtd10">8.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">170</td>
</tr>
<tr>
<td class="model prodtd1">LH 30/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">320</td>
<td class="prodtd4">320</td>
<td class="prodtd5">320</td>
<td class="prodtd6">30</td>
<td class="prodtd7">710</td>
<td class="prodtd8">930</td>
<td class="prodtd9">1290</td>
<td class="prodtd10">10.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">200</td>
</tr>
<tr>
<td class="model prodtd1">LH 60/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">400</td>
<td class="prodtd4">400</td>
<td class="prodtd5">400</td>
<td class="prodtd6">60</td>
<td class="prodtd7">790</td>
<td class="prodtd8">1080</td>
<td class="prodtd9">1370</td>
<td class="prodtd10">12.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">300</td>
</tr>
<tr>
<td class="model prodtd1">LH 120/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">500</td>
<td class="prodtd4">500</td>
<td class="prodtd5">500</td>
<td class="prodtd6">120</td>
<td class="prodtd7">890</td>
<td class="prodtd8">1180</td>
<td class="prodtd9">1470</td>
<td class="prodtd10">18.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">410</td>
</tr>
<tr>
<td class="model prodtd1">LH 216/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">600</td>
<td class="prodtd4">600</td>
<td class="prodtd5">600</td>
<td class="prodtd6">216</td>
<td class="prodtd7">990</td>
<td class="prodtd8">1280</td>
<td class="prodtd9">1590</td>
<td class="prodtd10">26.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">470</td>
</tr>
<tr>
<td class="model prodtd1"></td>
<td class="prodtd2"></td>
<td class="prodtd3"></td>
<td class="prodtd4"></td>
<td class="prodtd5"></td>
<td class="prodtd6"></td>
<td class="prodtd7"></td>
<td class="prodtd8"></td>
<td class="prodtd9"></td>
<td class="prodtd10"></td>
<td class="prodtd11"></td>
<td class="prodtd12"></td>
</tr>
<tr>
<td class="model prodtd1">LF 15/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">250</td>
<td class="prodtd4">250</td>
<td class="prodtd5">250</td>
<td class="prodtd6">15</td>
<td class="prodtd7">680</td>
<td class="prodtd8">860</td>
<td class="prodtd9">1230</td>
<td class="prodtd10">7.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">150</td>
</tr>
<tr>
<td class="model prodtd1">LF 30/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">320</td>
<td class="prodtd4">320</td>
<td class="prodtd5">320</td>
<td class="prodtd6">30</td>
<td class="prodtd7">710</td>
<td class="prodtd8">930</td>
<td class="prodtd9">1290</td>
<td class="prodtd10">8.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">180</td>
</tr>
<tr>
<td class="model prodtd1">LF 60/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">400</td>
<td class="prodtd4">400</td>
<td class="prodtd5">400</td>
<td class="prodtd6">60</td>
<td class="prodtd7">790</td>
<td class="prodtd8">1080</td>
<td class="prodtd9">1370</td>
<td class="prodtd10">11.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">270</td>
</tr>
<tr>
<td class="model prodtd1">LF 120/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">500</td>
<td class="prodtd4">500</td>
<td class="prodtd5">500</td>
<td class="prodtd6">120</td>
<td class="prodtd7">890</td>
<td class="prodtd8">1180</td>
<td class="prodtd9">1470</td>
<td class="prodtd10">15.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">370</td>
</tr>
<tr>
<td class="model prodtd1"></td>
<td class="prodtd2"></td>
<td class="prodtd3"></td>
<td class="prodtd4"></td>
<td class="prodtd5"></td>
<td class="prodtd6"></td>
<td class="prodtd7"></td>
<td class="prodtd8"></td>
<td class="prodtd9"></td>
<td class="prodtd10"></td>
<td class="prodtd11"></td>
<td class="prodtd12"></td>
</tr>
<tr>
<td class="model prodtd1">LF 15/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">250</td>
<td class="prodtd4">250</td>
<td class="prodtd5">250</td>
<td class="prodtd6">15</td>
<td class="prodtd7">680</td>
<td class="prodtd8">860</td>
<td class="prodtd9">1230</td>
<td class="prodtd10">8.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">150</td>
</tr>
<tr>
<td class="model prodtd1">LF 30/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">320</td>
<td class="prodtd4">320</td>
<td class="prodtd5">320</td>
<td class="prodtd6">30</td>
<td class="prodtd7">710</td>
<td class="prodtd8">930</td>
<td class="prodtd9">1290</td>
<td class="prodtd10">10.0</td>
<td class="prodtd11">3-phase<sup class="hks">2</sup></td>
<td class="prodtd12">180</td>
</tr>
<tr>
<td class="model prodtd1">LF 60/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">400</td>
<td class="prodtd4">400</td>
<td class="prodtd5">400</td>
<td class="prodtd6">60</td>
<td class="prodtd7">790</td>
<td class="prodtd8">1080</td>
<td class="prodtd9">1370</td>
<td class="prodtd10">12.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">270</td>
</tr>
<tr>
<td class="model prodtd1">LF 120/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">500</td>
<td class="prodtd4">500</td>
<td class="prodtd5">500</td>
<td class="prodtd6">120</td>
<td class="prodtd7">890</td>
<td class="prodtd8">1180</td>
<td class="prodtd9">1470</td>
<td class="prodtd10">18.0</td>
<td class="prodtd11">3-phase</td>
<td class="prodtd12">370</td>
</tr>
<tr class="tblfooter">
<td colspan="12"><sup class="hks">1</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.*Please see page 75 for more information about supply voltage<br />
<sup class="hks">2</sup>Heating only between two phases</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/chamber-furnaces-with-brick-insulation-or-fiber-insulation-up-to-1400-c/">Chamber Furnaces with Brick Insulation or Fiber Insulation up to 1400 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Muffle Furnace incl. Scale and Software for Determination of Combustion Loss</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnace-incl-scale-and-software-for-determination-of-combustion-loss/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 13:01:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19125</guid>

					<description><![CDATA[<p>Delivery includes base, ceramic plunger with base plate in the furnace lining, precision scale and software package.</p>
<p>This weighing furnace with integrated precision scale and software, was designed especially for combustion loss determination in the laboratory. The determination of combustion loss is necessary, for instance, when analyzing sludges and household garbage, and is also used in a variety of other processes for the evaluation of results. The difference between the charged total mass and the combustion residue is the combustion loss. During the process, the software included records both the temperature and the weight loss.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Like muffle furnaces L(T), except:</li>
<li>Delivery includes base, ceramic plunger with base plate in the furnace lining, precision scale and software package</li>
<li>4 scales available for different maximum weights and scaling ranges</li>
<li>Process control and documentation for temperature and combustion loss via VCD software package for monitoring, documentation and control</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
</ul>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnace-incl-scale-and-software-for-determination-of-combustion-loss/">Muffle Furnace incl. Scale and Software for Determination of Combustion Loss</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Delivery includes base, ceramic plunger with base plate in the furnace lining, precision scale and software package.</p>
<p>This weighing furnace with integrated precision scale and software, was designed especially for combustion loss determination in the laboratory. The determination of combustion loss is necessary, for instance, when analyzing sludges and household garbage, and is also used in a variety of other processes for the evaluation of results. The difference between the charged total mass and the combustion residue is the combustion loss. During the process, the software included records both the temperature and the weight loss.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Like muffle furnaces L(T), except:</li>
<li>Delivery includes base, ceramic plunger with base plate in the furnace lining, precision scale and software package</li>
<li>4 scales available for different maximum weights and scaling ranges</li>
<li>Process control and documentation for temperature and combustion loss via VCD software package for monitoring, documentation and control</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Model</th>
<th>Tmax</th>
<th colspan="3">Inner dimensions in mm</th>
<th>Volume</th>
<th colspan="3">Outer dimensions<sup class="hks">2</sup> in mm</th>
<th>Connected</th>
<th>Electrical</th>
<th>Weight</th>
<th>Heating time</th>
</tr>
<tr>
<th class="model"></th>
<th>in °C<sup class="hks">1</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in l</th>
<th>W</th>
<th>D</th>
<th>H</th>
<th>load in kW</th>
<th>connection*</th>
<th>in kg</th>
<th>in min<sup class="hks">4</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">L(T) 9/11/SW</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">230</td>
<td class="prodtd4">240</td>
<td class="prodtd5">170</td>
<td class="prodtd6">9</td>
<td class="prodtd7">415</td>
<td class="prodtd8">455</td>
<td class="prodtd9">740+240<sup class="hks">3</sup></td>
<td class="prodtd10">3.0</td>
<td class="prodtd11">1-phase</td>
<td class="prodtd12">50</td>
<td class="prodtd13">65</td>
</tr>
<tr>
<td class="model prodtd1">L(T) 9/12/SW</td>
<td class="prodtd2">1200</td>
<td class="prodtd3">230</td>
<td class="prodtd4">240</td>
<td class="prodtd5">170</td>
<td class="prodtd6">9</td>
<td class="prodtd7">415</td>
<td class="prodtd8">455</td>
<td class="prodtd9">740+240<sup class="hks">3</sup></td>
<td class="prodtd10">3.0</td>
<td class="prodtd11">1-phase</td>
<td class="prodtd12">50</td>
<td class="prodtd13">75</td>
</tr>
<tr class="tblfooter">
<td colspan="13"><sup class="hks">1</sup>Recommended working temperature for processes with longer dwell times is 1000 °C (L 9/11) rsp. 1100 °C (L 9/12)*Please see page 75 for more information about supply voltage<br />
<sup class="hks">2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup class="hks">3</sup>Including opened lift door (Model LT ..)<br />
<sup class="hks">4</sup>Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Scale</th>
<th>Readability</th>
<th>Maximum weighing range</th>
<th>Weight of plunger</th>
<th>Calibration value</th>
<th>Minimum load</th>
</tr>
<tr>
<th class="model">type</th>
<th>in g</th>
<th>in g</th>
<th>in g</th>
<th>in g</th>
<th>in g</th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">EW-2200</td>
<td class="prodtd2">0.01</td>
<td class="prodtd3">2200 incl. plunger</td>
<td class="prodtd4">850</td>
<td class="prodtd5">0.1</td>
<td class="prodtd6">0.5</td>
</tr>
<tr>
<td class="model prodtd1">EW-4200</td>
<td class="prodtd2">0.01</td>
<td class="prodtd3">4200 incl. plunger</td>
<td class="prodtd4">850</td>
<td class="prodtd5">0.1</td>
<td class="prodtd6">0.5</td>
</tr>
<tr>
<td class="model prodtd1">EW-6200</td>
<td class="prodtd2">0.01</td>
<td class="prodtd3">6200 incl. plunger</td>
<td class="prodtd4">850</td>
<td class="prodtd5">&#8211;</td>
<td class="prodtd6">1.0</td>
</tr>
<tr>
<td class="model prodtd1">EW-12000</td>
<td class="prodtd2">0.10</td>
<td class="prodtd3">12000 incl. plunger</td>
<td class="prodtd4">850</td>
<td class="prodtd5">1.0</td>
<td class="prodtd6">5.0</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnace-incl-scale-and-software-for-determination-of-combustion-loss/">Muffle Furnace incl. Scale and Software for Determination of Combustion Loss</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Ashing Furnaces with Integrated Exhaust Gas Cleaning up to 1100 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/ashing-furnaces-with-integrated-exhaust-gas-cleaning-up-to-1100-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 12:52:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19114</guid>

					<description><![CDATA[<p>The ashing furnace L ../11 BO is specially designed for processes in which larger sample quantities have to be incinerated. Fields of application are e.g. the ashing of food, thermal cleaning of injection molding tools or the determination of annealing loss. Another application is the debinding of ceramic products, e.g. after additive production.</p>
<p>The ashing furnaces have a passive safety system and integrated exhaust gas post combustion. An exhaust gas fan extracts flue gases from the furnace and simultaneously supplies fresh air to the furnace atmosphere with the result that sufficient oxygen is always available for the incineration process. The incoming air is guided behind the furnace heating and preheated to ensure good temperature uniformity. Exhaust gases are led from the furnace chamber to the integrated post combustion system, where they are postburned and catalytically cleaned. Directly after the incineration process (up to max. 600 °C) a subsequent process up to max. 1100 °C can take place.</p>
<h3 class="prodlisthead">Standard Equipment</h3>
<ul class="prodlist">
<li>Tmax 600 °C for the incineration process</li>
<li>Tmax 1100 °C for the subsequent process</li>
<li>Three-side heating (both sides and bottom)</li>
<li>Ceramic heating plates with embedded heating wire</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Steel collecting pan protects the bottom insulation</li>
<li>Spring-assisted closing of the furnace door (flap door) with mechanical locking against unintentional opening</li>
<li>Thermal/catalytic post combustion, integrated in the exhaust channel, up to 600  °C in function</li>
<li>Temperature control of post combustion can be set up to 850 °C</li>
<li>Monitored exhaust air</li>
<li>Inlet-air preheated through the bottom heating plate</li>
<li>Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load</li>
<li>Controller C550 (10 programs with each 20 segments)</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/ashing-furnaces-with-integrated-exhaust-gas-cleaning-up-to-1100-c/">Ashing Furnaces with Integrated Exhaust Gas Cleaning up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The ashing furnaces have a passive safety system and integrated exhaust gas post combustion.</p>
<p>The ashing furnace L ../11 BO is specially designed for processes in which larger sample quantities have to be incinerated. Fields of application are e.g. the ashing of food, thermal cleaning of injection molding tools or the determination of annealing loss. Another application is the debinding of ceramic products, e.g. after additive production.</p>
<p>The ashing furnaces have a passive safety system and integrated exhaust gas post combustion. An exhaust gas fan extracts flue gases from the furnace and simultaneously supplies fresh air to the furnace atmosphere with the result that sufficient oxygen is always available for the incineration process. The incoming air is guided behind the furnace heating and preheated to ensure good temperature uniformity. Exhaust gases are led from the furnace chamber to the integrated post combustion system, where they are postburned and catalytically cleaned. Directly after the incineration process (up to max. 600 °C) a subsequent process up to max. 1100 °C can take place.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 600 °C for the incineration process</li>
<li>Tmax 1100 °C for the subsequent process</li>
<li>Three-side heating (both sides and bottom)</li>
<li>Ceramic heating plates with embedded heating wire</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Steel collecting pan protects the bottom insulation</li>
<li>Spring-assisted closing of the furnace door (flap door) with mechanical locking against unintentional opening</li>
<li>Thermal/catalytic post combustion, integrated in the exhaust channel, up to 600  °C in function</li>
<li>Temperature control of post combustion can be set up to 850 °C</li>
<li>Monitored exhaust air</li>
<li>Inlet-air preheated through the bottom heating plate</li>
<li>Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load</li>
<li>Controller C550 (10 programs with each 20 segments)</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Model</th>
<th>Tmax</th>
<th colspan="3">Inner dimensions in mm</th>
<th>Volume</th>
<th colspan="3">Outer dimensions<sup class="hks">2</sup> in mm</th>
<th>Max. weight of hydrocarbons</th>
<th>Max. evaporation rate</th>
<th>Connected load</th>
<th>Electrical</th>
<th>Weight</th>
</tr>
<tr>
<th class="model"></th>
<th>in °C<sup class="hks">1</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in l</th>
<th>W</th>
<th>D</th>
<th>H<sup class="hks">3</sup></th>
<th>in g</th>
<th>g/min</th>
<th>in kW</th>
<th>connection*</th>
<th>in kg</th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">L 9/11 BO</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">230</td>
<td class="prodtd4">240</td>
<td class="prodtd5">170</td>
<td class="prodtd6">9</td>
<td class="prodtd7">415</td>
<td class="prodtd8">575</td>
<td class="prodtd9">750</td>
<td class="prodtd10">75</td>
<td class="prodtd11">1.0</td>
<td class="prodtd12">7.0</td>
<td class="prodtd13">3-phase</td>
<td class="prodtd14">60</td>
</tr>
<tr>
<td class="model prodtd1">L 24/11 BO</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">280</td>
<td class="prodtd4">340</td>
<td class="prodtd5">250</td>
<td class="prodtd6">24</td>
<td class="prodtd7">490</td>
<td class="prodtd8">675</td>
<td class="prodtd9">800</td>
<td class="prodtd10">150</td>
<td class="prodtd11">2.0</td>
<td class="prodtd12">9.0</td>
<td class="prodtd13">3-phase</td>
<td class="prodtd14">90</td>
</tr>
<tr>
<td class="model prodtd1">L 40/11 BO</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">320</td>
<td class="prodtd4">490</td>
<td class="prodtd5">250</td>
<td class="prodtd6">40</td>
<td class="prodtd7">530</td>
<td class="prodtd8">825</td>
<td class="prodtd9">800</td>
<td class="prodtd10">200</td>
<td class="prodtd11">2.1</td>
<td class="prodtd12">11.5</td>
<td class="prodtd13">3-phase</td>
<td class="prodtd14">110</td>
</tr>
<tr class="tblfooter">
<td colspan="14"><sup class="hks">1</sup>Recommended working temperature for processes with longer dwell times is 1000 °C*Please see page 75 for more information about supply voltage<br />
<sup class="hks">2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup class="hks">3</sup>Including exhaust tube (Ø 80 mm</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/ashing-furnaces-with-integrated-exhaust-gas-cleaning-up-to-1100-c/">Ashing Furnaces with Integrated Exhaust Gas Cleaning up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Ashing Furnaces up to 1100 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/ashing-furnaces-up-to-1100-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 12:47:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19107</guid>

					<description><![CDATA[<p>process.</p>
<p>Ashing furnace LV ../11 is designed especially for ashing processes to 1050 °C in the laboratory. Applications include determining loss on ignition, ashing food and plastics for subsequent substance analysis. A special fresh-air and exhaust air system ensures that the air is replaced 6 times per minute so that there is always sufficient oxygen for the ashing process. Incoming air passes the furnace heating and is pre-heated to ensure good temperature uniformity.</p>
<h3 class="prodlisthead">Standard Equipment</h3>
<ul class="prodlist">
<li>Tmax 1100 °C</li>
<li>Heating from two sides</li>
<li>Ceramic heating plates with integral heating element which is safeguarded, and easy to replace</li>
<li>Air exchange of more than 6 times per minute</li>
<li>Good temperature uniformity due to preheating of incoming air, temperature uniformity according to DIN 17052-1 to +/− 10 °C in the defined empty work area (from 550  °C)</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Suitable for many standardized ashing processes according to ISO, ASTM, EN, and DIN</li>
<li>Optional flap door (LV) which can be used as work platform or lift door (LVT) with hot surface facing away from the operator</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/ashing-furnaces-up-to-1100-c/">Ashing Furnaces up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>A special fresh-air and exhaust air system ensures that the air is replaced 6 times per minute so that there is always sufficient oxygen for the ashing process.</p>
<p>Ashing furnace LV ../11 is designed especially for ashing processes to 1050 °C in the laboratory. Applications include determining loss on ignition, ashing food and plastics for subsequent substance analysis. A special fresh-air and exhaust air system ensures that the air is replaced 6 times per minute so that there is always sufficient oxygen for the ashing process. Incoming air passes the furnace heating and is pre-heated to ensure good temperature uniformity.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1100 °C</li>
<li>Heating from two sides</li>
<li>Ceramic heating plates with integral heating element which is safeguarded, and easy to replace</li>
<li>Air exchange of more than 6 times per minute</li>
<li>Good temperature uniformity due to preheating of incoming air, temperature uniformity according to DIN 17052-1 to +/− 10 °C in the defined empty work area (from 550  °C)</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Suitable for many standardized ashing processes according to ISO, ASTM, EN, and DIN</li>
<li>Optional flap door (LV) which can be used as work platform or lift door (LVT) with hot surface facing away from the operator</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table id="data-table-en" lang="en">
<thead>
<tr>
<th colspan="1" rowspan="1">Model</th>
<th colspan="1" rowspan="1">Tmax</th>
<th colspan="3" rowspan="1">Inner dimensions in mm</th>
<th colspan="1" rowspan="1">Volume</th>
<th colspan="3" rowspan="1">Outer dimensions<sup>2</sup> in mm</th>
<th colspan="1" rowspan="1">Max. weight of hydrocarbons</th>
<th colspan="1" rowspan="1">Max. evaporation rate</th>
<th colspan="1" rowspan="1">Connected<br />
load</th>
<th colspan="1" rowspan="1">Electrical</th>
<th colspan="1" rowspan="1">Weight</th>
<th colspan="1" rowspan="1">Heating time</th>
</tr>
<tr>
<th colspan="1" rowspan="1">Flap door</th>
<th colspan="1" rowspan="1">in °C<sup>1</sup></th>
<th colspan="1" rowspan="1">w</th>
<th colspan="1" rowspan="1">d</th>
<th colspan="1" rowspan="1">h</th>
<th colspan="1" rowspan="1">in l</th>
<th colspan="1" rowspan="1">W</th>
<th colspan="1" rowspan="1">D</th>
<th colspan="1" rowspan="1">H<sup>3</sup></th>
<th colspan="1" rowspan="1">in g</th>
<th colspan="1" rowspan="1">g/min</th>
<th colspan="1" rowspan="1">in kW</th>
<th colspan="1" rowspan="1">connection</th>
<th colspan="1" rowspan="1">in kg</th>
<th colspan="1" rowspan="1">in min<sup>4</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="1" rowspan="1">LV 3/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">180</td>
<td colspan="1" rowspan="1">150</td>
<td colspan="1" rowspan="1">120</td>
<td colspan="1" rowspan="1">3</td>
<td colspan="1" rowspan="1">345</td>
<td colspan="1" rowspan="1">390</td>
<td colspan="1" rowspan="1">810</td>
<td colspan="1" rowspan="1">5</td>
<td colspan="1" rowspan="1">0,1</td>
<td colspan="1" rowspan="1">1.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">35</td>
<td colspan="1" rowspan="1">45</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LV 5/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">205</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">130</td>
<td colspan="1" rowspan="1">5</td>
<td colspan="1" rowspan="1">385</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">810</td>
<td colspan="1" rowspan="1">10</td>
<td colspan="1" rowspan="1">0,2</td>
<td colspan="1" rowspan="1">2.4</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">41</td>
<td colspan="1" rowspan="1">55</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LV 9/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">235</td>
<td colspan="1" rowspan="1">240</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">9</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">485</td>
<td colspan="1" rowspan="1">865</td>
<td colspan="1" rowspan="1">15</td>
<td colspan="1" rowspan="1">0,3</td>
<td colspan="1" rowspan="1">3.0</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">50</td>
<td colspan="1" rowspan="1">70</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LV 15/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">230</td>
<td colspan="1" rowspan="1">340</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">15</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">590</td>
<td colspan="1" rowspan="1">865</td>
<td colspan="1" rowspan="1">25</td>
<td colspan="1" rowspan="1">0,3</td>
<td colspan="1" rowspan="1">3.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">61</td>
<td colspan="1" rowspan="1">80</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table id="data-table-en--2" lang="en">
<thead>
<tr>
<th colspan="1" rowspan="1">Model</th>
<th colspan="1" rowspan="1">Tmax</th>
<th colspan="3" rowspan="1">Inner dimensions in mm</th>
<th colspan="1" rowspan="1">Volume</th>
<th colspan="3" rowspan="1">Outer dimensions<sup>2</sup> in mm</th>
<th colspan="1" rowspan="1">Max. weight of hydrocarbons</th>
<th colspan="1" rowspan="1">Max. evaporation rate</th>
<th colspan="1" rowspan="1">Connected load</th>
<th colspan="1" rowspan="1">Electrical</th>
<th colspan="1" rowspan="1">Weight</th>
<th colspan="1" rowspan="1">Heating time</th>
</tr>
<tr>
<th colspan="1" rowspan="1">Lift door</th>
<th colspan="1" rowspan="1">in °C<sup>1</sup></th>
<th colspan="1" rowspan="1">w</th>
<th colspan="1" rowspan="1">d</th>
<th colspan="1" rowspan="1">h</th>
<th colspan="1" rowspan="1">in l</th>
<th colspan="1" rowspan="1">W</th>
<th colspan="1" rowspan="1">D</th>
<th colspan="1" rowspan="1">H<sup>3</sup></th>
<th colspan="1" rowspan="1">in g</th>
<th colspan="1" rowspan="1">g/min</th>
<th colspan="1" rowspan="1">in kW</th>
<th colspan="1" rowspan="1">connection</th>
<th colspan="1" rowspan="1">in kg</th>
<th colspan="1" rowspan="1">in min<sup>4</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="1" rowspan="1">LVT 3/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">180</td>
<td colspan="1" rowspan="1">150</td>
<td colspan="1" rowspan="1">120</td>
<td colspan="1" rowspan="1">3</td>
<td colspan="1" rowspan="1">345</td>
<td colspan="1" rowspan="1">390</td>
<td colspan="1" rowspan="1">810</td>
<td colspan="1" rowspan="1">5</td>
<td colspan="1" rowspan="1">0,1</td>
<td colspan="1" rowspan="1">1.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">35</td>
<td colspan="1" rowspan="1">45</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LVT 5/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">205</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">130</td>
<td colspan="1" rowspan="1">5</td>
<td colspan="1" rowspan="1">385</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">810</td>
<td colspan="1" rowspan="1">10</td>
<td colspan="1" rowspan="1">0,2</td>
<td colspan="1" rowspan="1">2.4</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">41</td>
<td colspan="1" rowspan="1">55</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LVT 9/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">235</td>
<td colspan="1" rowspan="1">240</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">9</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">485</td>
<td colspan="1" rowspan="1">865</td>
<td colspan="1" rowspan="1">15</td>
<td colspan="1" rowspan="1">0,3</td>
<td colspan="1" rowspan="1">3.0</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">50</td>
<td colspan="1" rowspan="1">70</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LVT 15/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">230</td>
<td colspan="1" rowspan="1">340</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">15</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">590</td>
<td colspan="1" rowspan="1">865</td>
<td colspan="1" rowspan="1">25</td>
<td colspan="1" rowspan="1">0,3</td>
<td colspan="1" rowspan="1">3.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">61</td>
<td colspan="1" rowspan="1">80</td>
</tr>
</tbody>
<tfoot>
<tr>
<td colspan="15" rowspan="1"><sup>1</sup>Recommended working temperature for processes with longer dwell times is 1000 °C<br />
<sup>2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup>3</sup>Including exhaust tube (Ø 80 mm)<br />
<sup>4</sup>Approx. heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)</td>
</tr>
</tfoot>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/ashing-furnaces-up-to-1100-c/">Ashing Furnaces up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Muffle Furnaces with Embedded Heating Elements in the Ceramic Muffle up to 1100 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-with-embedded-heating-elements-in-the-ceramic-muffle-up-to-1100-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 12:45:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19101</guid>

					<description><![CDATA[<p>Furnace chamber with embedded ceramic muffle, high resistance to aggressive gasses and vapours.</p>
<p>We particularly recommend the muffle furnace L 9/11/SKM for heat treatment of aggressive substances. The furnace has a ceramic muffle with embedded heating from four sides. The muffle furnace thus combines a very good temperature uniformity with excellent protection of the heating elements from aggressive atmospheres. Another aspect is the smooth, nearly particle free muffle (furnace door made of fiber insulation), an important quality feature.</p>
<h3 class="prodlisthead">Standard Equipment</h3>
<ul class="prodlist">
<li>Tmax 1100 °C</li>
<li>Muffle heated from four sides</li>
<li>Furnace chamber with embedded ceramic muffle, high resistance to aggressive gasses and vapours</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator</li>
<li>Adjustable working air inlet in the door</li>
<li>Exhaust air outlet in rear wall of furnace</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-with-embedded-heating-elements-in-the-ceramic-muffle-up-to-1100-c/">Muffle Furnaces with Embedded Heating Elements in the Ceramic Muffle up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Furnace chamber with embedded ceramic muffle, high resistance to aggressive gasses and vapours.</p>
<p>We particularly recommend the muffle furnace L 9/11/SKM for heat treatment of aggressive substances. The furnace has a ceramic muffle with embedded heating from four sides. The muffle furnace thus combines a very good temperature uniformity with excellent protection of the heating elements from aggressive atmospheres. Another aspect is the smooth, nearly particle free muffle (furnace door made of fiber insulation), an important quality feature.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1100 °C</li>
<li>Muffle heated from four sides</li>
<li>Furnace chamber with embedded ceramic muffle, high resistance to aggressive gasses and vapours</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator</li>
<li>Adjustable working air inlet in the door</li>
<li>Exhaust air outlet in rear wall of furnace</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Modell</th>
<th>Tmax</th>
<th colspan="3">Inner dimensions in mm</th>
<th>Volume</th>
<th colspan="3">Outer dimensions<sup class="hks">2</sup> in mm</th>
<th>Connected</th>
<th>Electrical</th>
<th>Weight</th>
<th>Heating time</th>
</tr>
<tr>
<th class="model"></th>
<th>in °C<sup class="hks">1</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in l</th>
<th>W</th>
<th>D</th>
<th>H</th>
<th>load in kW</th>
<th>connection*</th>
<th>in kg</th>
<th>in min<sup class="hks">4</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">L 9/11/SKM</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">230</td>
<td class="prodtd4">240</td>
<td class="prodtd5">170</td>
<td class="prodtd6">9</td>
<td class="prodtd7">490</td>
<td class="prodtd8">505</td>
<td class="prodtd9">580</td>
<td class="prodtd10">3.4</td>
<td class="prodtd11">1-phase</td>
<td class="prodtd12">50</td>
<td class="prodtd13">75</td>
</tr>
<tr>
<td class="model prodtd1">LT 9/11/SKM</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">230</td>
<td class="prodtd4">240</td>
<td class="prodtd5">170</td>
<td class="prodtd6">9</td>
<td class="prodtd7">490</td>
<td class="prodtd8">505</td>
<td class="prodtd9">580+320<sup class="hks">3</sup></td>
<td class="prodtd10">3.4</td>
<td class="prodtd11">1-phase</td>
<td class="prodtd12">50</td>
<td class="prodtd13">75</td>
</tr>
<tr class="tblfooter">
<td colspan="13"><sup class="hks">1</sup>Recommended working temperature for processes with longer dwell times is 1000 °C*Please see page 75 for more information about supply voltage<br />
<sup class="hks">2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup class="hks">3</sup>Including opened lift door<br />
<sup class="hks">4</sup>Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-with-embedded-heating-elements-in-the-ceramic-muffle-up-to-1100-c/">Muffle Furnaces with Embedded Heating Elements in the Ceramic Muffle up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Muffle Furnaces up to 1400 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-up-to-1400-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 12:36:10 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19098</guid>

					<description><![CDATA[<p>Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times and a maximum temperature of 1400 °C.</p>
<p>These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times and a maximum temperature of 1400 °C. These muffle furnaces are a good alternative to the familiar L(T) ../12 series when higher application temperatures are needed.</p>
<h3 class="prodlisthead">Standard Equipment</h3>
<ul class="prodlist">
<li>Tmax 1400 °C</li>
<li>Heating from two sides</li>
<li>Heating elements on support tubes ensure free heat radiation and a long service life</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Adjustable air inlet integrated in door</li>
<li>Exhaust air outlet in rear wall of furnace</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-up-to-1400-c/">Muffle Furnaces up to 1400 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times and a maximum temperature of 1400 °C.</p>
<p>These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times and a maximum temperature of 1400 °C. These muffle furnaces are a good alternative to the familiar L(T) ../12 series when higher application temperatures are needed.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1400 °C</li>
<li>Heating from two sides</li>
<li>Heating elements on support tubes ensure free heat radiation and a long service life</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Adjustable air inlet integrated in door</li>
<li>Exhaust air outlet in rear wall of furnace</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Model</th>
<th>Tmax</th>
<th colspan="3">Inner dimensions in mm</th>
<th>Volume</th>
<th colspan="3">Outer dimensions<sup class="hks">2</sup> in mm</th>
<th colspan="3">Temperature uniformity of +/− 5K in the empty workspace<sup class="hks">5</sup></th>
<th>Connected load</th>
<th>Electrical</th>
<th>Weight</th>
<th>Heating time</th>
</tr>
<tr>
<th class="model"></th>
<th>in °C<sup class="hks">1</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in l</th>
<th>W</th>
<th>D</th>
<th>H<sup class="hks">3</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in kW</th>
<th>connection*</th>
<th>in kg</th>
<th>in min<sup class="hks">4</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">L, LT 5/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">200</td>
<td class="prodtd4">170</td>
<td class="prodtd5">130</td>
<td class="prodtd6">5</td>
<td class="prodtd7">490</td>
<td class="prodtd8">450</td>
<td class="prodtd9">580+320</td>
<td class="prodtd10">170</td>
<td class="prodtd11">120</td>
<td class="prodtd12">80</td>
<td class="prodtd13">2.4</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">42</td>
<td class="prodtd16">50</td>
</tr>
<tr>
<td class="model prodtd1">L, LT 9/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">250</td>
<td class="prodtd4">250</td>
<td class="prodtd5">170</td>
<td class="prodtd6">9</td>
<td class="prodtd7">530</td>
<td class="prodtd8">525</td>
<td class="prodtd9">630+350</td>
<td class="prodtd10">180</td>
<td class="prodtd11">190</td>
<td class="prodtd12">120</td>
<td class="prodtd13">3.2</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">55</td>
<td class="prodtd16">50</td>
</tr>
<tr>
<td class="model prodtd1">L, LT 15/14</td>
<td class="prodtd2">1400</td>
<td class="prodtd3">250</td>
<td class="prodtd4">350</td>
<td class="prodtd5">170</td>
<td class="prodtd6">15</td>
<td class="prodtd7">530</td>
<td class="prodtd8">625</td>
<td class="prodtd9">630+350</td>
<td class="prodtd10">180</td>
<td class="prodtd11">290</td>
<td class="prodtd12">120</td>
<td class="prodtd13">3.2</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">63</td>
<td class="prodtd16">70</td>
</tr>
<tr class="tblfooter">
<td colspan="16"><sup class="hks">1</sup>Recommended working temperature for processes with longer dwell times is 1300 °C<br />
<sup class="hks">2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup class="hks">3</sup>Including opened lift door<br />
<sup class="hks">4</sup>Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)<br />
<sup class="hks">5</sup>Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-up-to-1400-c/">Muffle Furnaces up to 1400 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Muffle Furnaces with Brick Insulation up to 1300 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-with-brick-insulation-up-to-1300-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 12:15:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19092</guid>

					<description><![CDATA[<p>Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.</p>
<h3 class="prodlisthead">Standard Equipment</h3>
<ul class="prodlist">
<li>Tmax 1300 °C</li>
<li>Heating from two sides</li>
<li>Heating elements on support tubes ensure free heat radiation and a long service life</li>
<li>Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator</li>
<li>Adjustable air inlet in the furnace door</li>
<li>Exhaust air outlet in rear wall of furnace</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-with-brick-insulation-up-to-1300-c/">Muffle Furnaces with Brick Insulation up to 1300 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C.</p>
<p>Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1300 °C</li>
<li>Heating from two sides</li>
<li>Heating elements on support tubes ensure free heat radiation and a long service life</li>
<li>Multi-layer insulation with robust lightweight refractory bricks in the furnace chamber</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator</li>
<li>Adjustable air inlet in the furnace door</li>
<li>Exhaust air outlet in rear wall of furnace</li>
<li>Controller B510 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Model</th>
<th>Tmax</th>
<th colspan="3">Inner dimensions in mm</th>
<th>Volume</th>
<th colspan="3">Outer dimensions<sup class="hks">2</sup> in mm</th>
<th colspan="3">Temperature uniformity of +/− 5K in the empty workspace<sup class="hks">5</sup></th>
<th>Connected load</th>
<th>Electrical</th>
<th>Weight</th>
<th>Heating time</th>
</tr>
<tr>
<th class="model"></th>
<th>in °C<sup class="hks">1</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in l</th>
<th>W</th>
<th>D</th>
<th>H<sup class="hks">3</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in kW</th>
<th>connection*</th>
<th>in kg</th>
<th>in min<sup class="hks">4</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">L, LT 5/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">200</td>
<td class="prodtd4">170</td>
<td class="prodtd5">130</td>
<td class="prodtd6">5</td>
<td class="prodtd7">490</td>
<td class="prodtd8">450</td>
<td class="prodtd9">580+320</td>
<td class="prodtd10">170</td>
<td class="prodtd11">100</td>
<td class="prodtd12">80</td>
<td class="prodtd13">2.4</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">42</td>
<td class="prodtd16">60</td>
</tr>
<tr>
<td class="model prodtd1">L, LT 9/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">230</td>
<td class="prodtd4">240</td>
<td class="prodtd5">170</td>
<td class="prodtd6">9</td>
<td class="prodtd7">530</td>
<td class="prodtd8">525</td>
<td class="prodtd9">630+350</td>
<td class="prodtd10">180</td>
<td class="prodtd11">170</td>
<td class="prodtd12">120</td>
<td class="prodtd13">3.0</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">60</td>
<td class="prodtd16">60</td>
</tr>
<tr>
<td class="model prodtd1">L, LT 15/13</td>
<td class="prodtd2">1300</td>
<td class="prodtd3">230</td>
<td class="prodtd4">340</td>
<td class="prodtd5">170</td>
<td class="prodtd6">15</td>
<td class="prodtd7">530</td>
<td class="prodtd8">625</td>
<td class="prodtd9">630+350</td>
<td class="prodtd10">180</td>
<td class="prodtd11">270</td>
<td class="prodtd12">120</td>
<td class="prodtd13">3.2</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">70</td>
<td class="prodtd16">70</td>
</tr>
<tr class="tblfooter">
<td colspan="16"><sup class="hks">1</sup>Recommended working temperature for processes with longer dwell times is 1200 °C*Please see page 75 for more information about supply voltage<br />
<sup class="hks">2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup class="hks">3</sup>Including opened lift door (LT models)<br />
<sup class="hks">4</sup>Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)<br />
<sup class="hks">5</sup>Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-with-brick-insulation-up-to-1300-c/">Muffle Furnaces with Brick Insulation up to 1300 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Economy Muffle Furnaces up to 1100 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/economy-muffle-furnaces-up-to-1100-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 12:08:04 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19083</guid>

					<description><![CDATA[<p>Quality features like the dual shell furnace housing of rust-free stainless steel, their compact, lightweight constructions, or the heating elements encased in quartz glass tubes make these models reliable partners for your application.</p>
<p>With their convincing price/performance ratio and the fast heat-up rates, these compact muffle furnaces are perfect for many applications in the laboratory. Quality features like the dual shell furnace housing of rust-free stainless steel, their compact, lightweight constructions, or the heating elements encased in quartz glass tubes make these models reliable partners for your application.</p>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/economy-muffle-furnaces-up-to-1100-c/">Economy Muffle Furnaces up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Quality features like the dual shell furnace housing of rust-free stainless steel, their compact, lightweight constructions, or the heating elements encased in quartz glass tubes make these models reliable partners for your application.</p>
<p>With their convincing price/performance ratio and the fast heat-up rates, these compact muffle furnaces are perfect for many applications in the laboratory. Quality features like the dual shell furnace housing of rust-free stainless steel, their compact, lightweight constructions, or the heating elements encased in quartz glass tubes make these models reliable partners for your application.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1100 °C</li>
<li>Heating from two sides from heating elements protected in quartz glass tubes</li>
<li>Fast heating times (see table)</li>
<li>Maintenance-friendly replacement of heating elements and insulation</li>
<li>Housing coated in RAL 9003</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Flap door which can also be used as a work platform</li>
<li>Exhaust air outlet in rear wall</li>
<li>Compact dimensions and light weight</li>
<li>Controller mounted under the door to save space</li>
<li>Controller R7</li>
<li>Defined application within the constraints of the operating instructions.</li>
</ul>
<div id="tab-1" class="tab-content swiper-slide first">
<div class="tab-item" data-title="Function and equipment" data-id="tab-1">
<div class="col-xs-12 col-sm-4 margin-bottom">
<div id="producte-slide_0" class="swiper-container producte-slide swiper-container-initialized swiper-container-horizontal swiper-container-autoheight"></div>
<div class="product-gallery-caption">
<h3 class="prodlisthead"><strong>Specifications</strong></h3>
</div>
<div></div>
</div>
</div>
</div>
<div id="tab-4" class="tab-content swiper-slide swiper-slide-active">
<div class="tab-item col-xs-12" data-title="Technical specifications" data-id="tab-4">
<div class="field field--name-field-tabelle field--type-text-long field--label-hidden field__item">
<table class="prodtbl responsive">
<thead>
<tr>
<th class="model">Model</th>
<th>Tmax</th>
<th colspan="3">Inner dimensions in mm</th>
<th>Volume</th>
<th colspan="3">Outer dimensions<sup class="hks">2</sup> in mm</th>
<th colspan="3">Temperature uniformity of +/− 5K in the empty workspace<sup class="hks">4</sup></th>
<th>Connected</th>
<th>Electrical</th>
<th>Weight</th>
<th>Heating time</th>
</tr>
<tr>
<th class="model"></th>
<th>in °C<sup class="hks">1</sup></th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>in l</th>
<th>W</th>
<th>D</th>
<th>H</th>
<th>w</th>
<th>d</th>
<th>h</th>
<th>load in kW</th>
<th>connection*</th>
<th>in kg</th>
<th>in min<sup class="hks">3</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td class="model prodtd1">LE 1/11</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">90</td>
<td class="prodtd4">115</td>
<td class="prodtd5">110</td>
<td class="prodtd6">1</td>
<td class="prodtd7">290</td>
<td class="prodtd8">280</td>
<td class="prodtd9">410</td>
<td class="prodtd10">40</td>
<td class="prodtd11">65</td>
<td class="prodtd12">60</td>
<td class="prodtd13">1.6</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">15</td>
<td class="prodtd16">10</td>
</tr>
<tr>
<td class="model prodtd1">LE 2/11</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">110</td>
<td class="prodtd4">180</td>
<td class="prodtd5">110</td>
<td class="prodtd6">2</td>
<td class="prodtd7">330</td>
<td class="prodtd8">390</td>
<td class="prodtd9">410</td>
<td class="prodtd10">60</td>
<td class="prodtd11">130</td>
<td class="prodtd12">60</td>
<td class="prodtd13">1.9</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">20</td>
<td class="prodtd16">15</td>
</tr>
<tr>
<td class="model prodtd1">LE 6/11</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">170</td>
<td class="prodtd4">200</td>
<td class="prodtd5">170</td>
<td class="prodtd6">6</td>
<td class="prodtd7">390</td>
<td class="prodtd8">440</td>
<td class="prodtd9">470</td>
<td class="prodtd10">120</td>
<td class="prodtd11">150</td>
<td class="prodtd12">120</td>
<td class="prodtd13">2.0</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">27</td>
<td class="prodtd16">30</td>
</tr>
<tr>
<td class="model prodtd1">LE 14/11</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">220</td>
<td class="prodtd4">300</td>
<td class="prodtd5">220</td>
<td class="prodtd6">14</td>
<td class="prodtd7">440</td>
<td class="prodtd8">540</td>
<td class="prodtd9">520</td>
<td class="prodtd10">170</td>
<td class="prodtd11">250</td>
<td class="prodtd12">170</td>
<td class="prodtd13">3.2</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">35</td>
<td class="prodtd16">35</td>
</tr>
<tr>
<td class="model prodtd1">LE 24/11</td>
<td class="prodtd2">1100</td>
<td class="prodtd3">260</td>
<td class="prodtd4">330</td>
<td class="prodtd5">280</td>
<td class="prodtd6">24</td>
<td class="prodtd7">490</td>
<td class="prodtd8">570</td>
<td class="prodtd9">590</td>
<td class="prodtd10">200</td>
<td class="prodtd11">270</td>
<td class="prodtd12">230</td>
<td class="prodtd13">3.5</td>
<td class="prodtd14">1-phase</td>
<td class="prodtd15">42</td>
<td class="prodtd16">40</td>
</tr>
<tr class="tblfooter">
<td colspan="16"><sup class="hks">1</sup>Recommended working temperature for processes with longer dwell times is 1050 °C*Please see page 75 for more information about supply voltage<br />
<sup class="hks">2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup class="hks">3</sup>Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)<br />
<sup class="hks">4</sup>Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/economy-muffle-furnaces-up-to-1100-c/">Economy Muffle Furnaces up to 1100 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Muffle Furnaces up to 1100 °C or 1200 °C</title>
		<link>https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-up-to-1100-c-or-1200-c/</link>
		
		<dc:creator><![CDATA[admingfh]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 09:41:27 +0000</pubDate>
				<guid isPermaLink="false">https://www.labsupply.co.za/?post_type=product&#038;p=19071</guid>

					<description><![CDATA[<p>The muffle furnaces L 3/11 &#8211; LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge. Standard Equipment Tmax 1100 °C or [&#8230;]</p>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-up-to-1100-c-or-1200-c/">Muffle Furnaces up to 1100 °C or 1200 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The muffle furnaces L 3/11 &#8211; LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.</p>
<h3 class="prodlisthead"><strong>Standard Equipment</strong></h3>
<ul class="prodlist">
<li>Tmax 1100 °C or 1200 °C</li>
<li>Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 &#8211; LT 60/12) for an optimal temperature uniformity</li>
<li>Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C</li>
<li>Thermocouple type N (1100 °C) or type S (1200 °C)</li>
<li>Ceramic heating plates with integral heating element which is safeguarded and easy to replace</li>
<li>Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator</li>
<li>Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature</li>
<li>Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)</li>
<li>Adjustable air inlet integrated in door (see illustration)</li>
<li>Exhaust air outlet in rear wall of furnace</li>
<li>Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)</li>
<li>Solid state relays provide for lownoise operation</li>
<li>Defined application within the constraints of the operating instructions</li>
<li>NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive</li>
</ul>
<h3 class="prodlisthead"><strong>Specification</strong></h3>
<table id="data-table-en" lang="en">
<thead>
<tr>
<th colspan="1" rowspan="1">Model</th>
<th colspan="1" rowspan="1">Tmax</th>
<th colspan="3" rowspan="1">Inner dimensions in mm</th>
<th colspan="1" rowspan="1">Volume</th>
<th colspan="3" rowspan="1">Outer dimensions<sup>2</sup> in mm</th>
<th colspan="3" rowspan="1">Temperature uniformity of +/− 5K in the empty workspace<sup>5</sup></th>
<th colspan="1" rowspan="1">Connected load</th>
<th colspan="1" rowspan="1">Electrical</th>
<th colspan="1" rowspan="1">Weight</th>
<th colspan="1" rowspan="1">Heating time</th>
</tr>
<tr>
<th colspan="1" rowspan="1"></th>
<th colspan="1" rowspan="1">in °C<sup>1</sup></th>
<th colspan="1" rowspan="1">w</th>
<th colspan="1" rowspan="1">d</th>
<th colspan="1" rowspan="1">h</th>
<th colspan="1" rowspan="1">in l</th>
<th colspan="1" rowspan="1">W</th>
<th colspan="1" rowspan="1">D</th>
<th colspan="1" rowspan="1">H<sup>3</sup></th>
<th colspan="1" rowspan="1">w</th>
<th colspan="1" rowspan="1">d</th>
<th colspan="1" rowspan="1">h</th>
<th colspan="1" rowspan="1">in kW</th>
<th colspan="1" rowspan="1">connection</th>
<th colspan="1" rowspan="1">in kg</th>
<th colspan="1" rowspan="1">in min<sup>4</sup></th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="1" rowspan="1">L(T) 3/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">160</td>
<td colspan="1" rowspan="1">140</td>
<td colspan="1" rowspan="1">100</td>
<td colspan="1" rowspan="1">3</td>
<td colspan="1" rowspan="1">385</td>
<td colspan="1" rowspan="1">330</td>
<td colspan="1" rowspan="1">405+155</td>
<td colspan="1" rowspan="1">110</td>
<td colspan="1" rowspan="1">50</td>
<td colspan="1" rowspan="1">50</td>
<td colspan="1" rowspan="1">1.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">21</td>
<td colspan="1" rowspan="1">41</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 5/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">205</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">130</td>
<td colspan="1" rowspan="1">5</td>
<td colspan="1" rowspan="1">385</td>
<td colspan="1" rowspan="1">390</td>
<td colspan="1" rowspan="1">460+205</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">80</td>
<td colspan="1" rowspan="1">80</td>
<td colspan="1" rowspan="1">2.4</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">27</td>
<td colspan="1" rowspan="1">47</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 9/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">235</td>
<td colspan="1" rowspan="1">240</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">9</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">455</td>
<td colspan="1" rowspan="1">515+240</td>
<td colspan="1" rowspan="1">180</td>
<td colspan="1" rowspan="1">150</td>
<td colspan="1" rowspan="1">120</td>
<td colspan="1" rowspan="1">3.0</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">35</td>
<td colspan="1" rowspan="1">63</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 15/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">230</td>
<td colspan="1" rowspan="1">340</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">15</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">555</td>
<td colspan="1" rowspan="1">515+240</td>
<td colspan="1" rowspan="1">180</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">120</td>
<td colspan="1" rowspan="1">3.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">43</td>
<td colspan="1" rowspan="1">74</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 24/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">280</td>
<td colspan="1" rowspan="1">340</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">24</td>
<td colspan="1" rowspan="1">490</td>
<td colspan="1" rowspan="1">555</td>
<td colspan="1" rowspan="1">580+320</td>
<td colspan="1" rowspan="1">230</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">200</td>
<td colspan="1" rowspan="1">4.5</td>
<td colspan="1" rowspan="1">3-phase</td>
<td colspan="1" rowspan="1">52</td>
<td colspan="1" rowspan="1">69</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 40/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">320</td>
<td colspan="1" rowspan="1">490</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">40</td>
<td colspan="1" rowspan="1">530</td>
<td colspan="1" rowspan="1">705</td>
<td colspan="1" rowspan="1">580+320</td>
<td colspan="1" rowspan="1">270</td>
<td colspan="1" rowspan="1">400</td>
<td colspan="1" rowspan="1">200</td>
<td colspan="1" rowspan="1">6.0</td>
<td colspan="1" rowspan="1">3-phase</td>
<td colspan="1" rowspan="1">70</td>
<td colspan="1" rowspan="1">80</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LT 60/11</td>
<td colspan="1" rowspan="1">1100</td>
<td colspan="1" rowspan="1">380</td>
<td colspan="1" rowspan="1">490</td>
<td colspan="1" rowspan="1">330</td>
<td colspan="1" rowspan="1">60</td>
<td colspan="1" rowspan="1">610</td>
<td colspan="1" rowspan="1">705</td>
<td colspan="1" rowspan="1">660+385</td>
<td colspan="1" rowspan="1">290</td>
<td colspan="1" rowspan="1">360</td>
<td colspan="1" rowspan="1">240</td>
<td colspan="1" rowspan="1">9,1</td>
<td colspan="1" rowspan="1">3-phase</td>
<td colspan="1" rowspan="1">83</td>
<td colspan="1" rowspan="1">150</td>
</tr>
<tr>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
<td colspan="1" rowspan="1"></td>
</tr>
<tr>
<td colspan="1" rowspan="1">L 1/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">90</td>
<td colspan="1" rowspan="1">115</td>
<td colspan="1" rowspan="1">110</td>
<td colspan="1" rowspan="1">1</td>
<td colspan="1" rowspan="1">290</td>
<td colspan="1" rowspan="1">280</td>
<td colspan="1" rowspan="1">410</td>
<td colspan="1" rowspan="1">40</td>
<td colspan="1" rowspan="1">45</td>
<td colspan="1" rowspan="1">60</td>
<td colspan="1" rowspan="1">1.5</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">15</td>
<td colspan="1" rowspan="1">25</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 3/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">160</td>
<td colspan="1" rowspan="1">140</td>
<td colspan="1" rowspan="1">100</td>
<td colspan="1" rowspan="1">3</td>
<td colspan="1" rowspan="1">385</td>
<td colspan="1" rowspan="1">330</td>
<td colspan="1" rowspan="1">405+155</td>
<td colspan="1" rowspan="1">110</td>
<td colspan="1" rowspan="1">50</td>
<td colspan="1" rowspan="1">50</td>
<td colspan="1" rowspan="1">1.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">21</td>
<td colspan="1" rowspan="1">48</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 5/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">205</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">130</td>
<td colspan="1" rowspan="1">5</td>
<td colspan="1" rowspan="1">385</td>
<td colspan="1" rowspan="1">390</td>
<td colspan="1" rowspan="1">460+205</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">80</td>
<td colspan="1" rowspan="1">80</td>
<td colspan="1" rowspan="1">2.4</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">27</td>
<td colspan="1" rowspan="1">59</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 9/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">235</td>
<td colspan="1" rowspan="1">240</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">9</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">455</td>
<td colspan="1" rowspan="1">515+240</td>
<td colspan="1" rowspan="1">180</td>
<td colspan="1" rowspan="1">150</td>
<td colspan="1" rowspan="1">120</td>
<td colspan="1" rowspan="1">3.0</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">35</td>
<td colspan="1" rowspan="1">78</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 15/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">230</td>
<td colspan="1" rowspan="1">340</td>
<td colspan="1" rowspan="1">170</td>
<td colspan="1" rowspan="1">15</td>
<td colspan="1" rowspan="1">415</td>
<td colspan="1" rowspan="1">555</td>
<td colspan="1" rowspan="1">515+240</td>
<td colspan="1" rowspan="1">180</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">120</td>
<td colspan="1" rowspan="1">3.2</td>
<td colspan="1" rowspan="1">1-phase</td>
<td colspan="1" rowspan="1">43</td>
<td colspan="1" rowspan="1">99</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 24/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">280</td>
<td colspan="1" rowspan="1">340</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">24</td>
<td colspan="1" rowspan="1">490</td>
<td colspan="1" rowspan="1">555</td>
<td colspan="1" rowspan="1">580+320</td>
<td colspan="1" rowspan="1">230</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">200</td>
<td colspan="1" rowspan="1">4.5</td>
<td colspan="1" rowspan="1">3-phase</td>
<td colspan="1" rowspan="1">52</td>
<td colspan="1" rowspan="1">82</td>
</tr>
<tr>
<td colspan="1" rowspan="1">L(T) 40/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">320</td>
<td colspan="1" rowspan="1">490</td>
<td colspan="1" rowspan="1">250</td>
<td colspan="1" rowspan="1">40</td>
<td colspan="1" rowspan="1">530</td>
<td colspan="1" rowspan="1">705</td>
<td colspan="1" rowspan="1">580+320</td>
<td colspan="1" rowspan="1">270</td>
<td colspan="1" rowspan="1">400</td>
<td colspan="1" rowspan="1">200</td>
<td colspan="1" rowspan="1">6.0</td>
<td colspan="1" rowspan="1">3-phase</td>
<td colspan="1" rowspan="1">70</td>
<td colspan="1" rowspan="1">97</td>
</tr>
<tr>
<td colspan="1" rowspan="1">LT 60/12</td>
<td colspan="1" rowspan="1">1200</td>
<td colspan="1" rowspan="1">380</td>
<td colspan="1" rowspan="1">490</td>
<td colspan="1" rowspan="1">330</td>
<td colspan="1" rowspan="1">60</td>
<td colspan="1" rowspan="1">610</td>
<td colspan="1" rowspan="1">705</td>
<td colspan="1" rowspan="1">660+385</td>
<td colspan="1" rowspan="1">290</td>
<td colspan="1" rowspan="1">360</td>
<td colspan="1" rowspan="1">240</td>
<td colspan="1" rowspan="1">9,1</td>
<td colspan="1" rowspan="1">3-phase</td>
<td colspan="1" rowspan="1">83</td>
<td colspan="1" rowspan="1">160</td>
</tr>
</tbody>
<tfoot>
<tr>
<td colspan="16" rowspan="1"><sup>1</sup>Recommended working temperature for processes with longer dwell times is 1000 °C (L../11) rsp. 1100 °C (L../12)<br />
<sup>2</sup>External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.<br />
<sup>3</sup>Including opened lift door (LT models)<br />
<sup>4</sup>Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE rsp. 400 V 3/N/PE)<br />
<sup>5</sup>Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C</td>
</tr>
</tfoot>
</table>
<p>The post <a href="https://www.labsupply.co.za/shop/furnaces/muffle-furnaces/muffle-furnaces-up-to-1100-c-or-1200-c/">Muffle Furnaces up to 1100 °C or 1200 °C</a> appeared first on <a href="https://www.labsupply.co.za">Laboratory Supplies Company (Pty) Ltd</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>